Description
2001 Electric Strike, 5-7/8″ Offset Cavity, Brass Powder Coat
For use in new or replacement wood or metal jamb installations with locksets having up to 5/8” throw, based on 1/8” door gap.
Face Plate 5-7/8” x 1-1/4” — Narrow Style Face Plate — Mortise Backset 1-9/16” — Cavity Depth 9/16” — Cavity Width 5/8” — Cavity Height 1-11/16”
Voltage | Current/Amps | Ohms (Ω) | Sound | Duty |
---|---|---|---|---|
6-14VAC | 0.44 – 1.10 | 8.5 | Buzz | Intermittent |
6-14VDC | 0.70 – 1.60 | 8.5 | Silent | Intermittent |
16-24VAC | 0.22 – 0.33 | 50.0 | Buzz | Intermittent |
16-24VDC | 0.32 – 0.47 | 50.0 | Silent | Intermittent |
12VDC | 0.20 – 0.33 | 60.0 | Silent | Continuous |
24VDC | 0.11 – 0.47 | 120.0 | Silent | Continuous |